The addressable carbon monoxide detector AW-D125A is an intelligent detector which can be configured with Asenware AW-FP200 series
addressable fire alarm control panel. Each point (device) can be given specific ID, which allows the panel to continuously monitor specific detector location (point).
It is equipped with a sturdy mounting bracket for quick, easy and secure installation.
In a Single-level Home:
Install at least one conventional CO detector near or within each separate sleeping area.
For additional protection, install an additional conventional CO detector at least 20 feet (6 meters) away from the furnace or fuel burning heat source.
In a Multi-level Home:
Install at least one conventional CO detector near or within each separate sleeping area.
For additional protection, install at least one conventional CO detector on each level of the home. If you have a basement, install conventional CO detector at the top of the basement stairs.
For additional protection, install an additional conventional CO detector at least 20 feet (6 meters) away from the furnace or fuel burning heat source.
Any extremely dusty, dirty or greasy areas.
Closer than 20 feet from a furnace or other fuel burning heat source, or fuel burning appliances like a water heater.
Within 5 feet of any cooking appliance.
Self diagnostic function by
MCU intelligent software. Excellent reliability & High stability. Ideal for all kitchens.