Flood merciless, but there is love in the world. When Asenware knew Bangladesh was in the midst of a flood disaster, On September 6th, Asenware, with the support of local partners, Four different Bangladeshi charities: As-Sunnah Foundation, trustful trading LTD, Bangladesh Red Crescent Society, Chief Advisor's Relief and Welfare Fund are donated by Asenware,
A fire hose is a highly pressurized hose that is used to bring water to the fire. It may also transport flame retardants. Fire hoses can be attached to either a fire engine or a fire hydrant, and the pressure is between 800 and 2000 kPa. For reasons of fire safety, it's quite important to have a fire hose inspection as well as all fire protection equipment tested. If, during a fire emergency, the fire hose fails it could have disastrous results.
Waterproof Heat Detector
Fixed Temperature Waterproof Heat Detector, the detector uses a bi-metallic strip to sense temperature change, therefore consuming minimal standby current and providing high reliability.
The Detector is particularly suited to environments, which are exposed to high levels of condensation or are hosed down. The detector has a wide operating margin allowing it to respond to both slow and fast increases in temperature; it can also sense temperature reliably in a horizontal or vertical position.
The Explosion Proof range of products has been designed to provide protection against explosions and products to ensure that all major advantages of high-quality fire detection technology can be safely exploited in industrial and hazardous environments. Many difficult sites such as metal, paint, pipelines, chemical, pharmaceutical, oil refineries, and other installations are vulnerable to the risk of explosion. In order to protect the assets and people, they need special solutions for fast and reliable fire detection.
Emergency lighting system is divided into centralized controlling and non-centralized controlling type, or centralized power supply and non-centralized power supply type. This article talks about emergency lighting system, power supply, emergency light controller installation guide.
Installing fire protection facilities and carry out regular maintenance are significant. This article talks about the inspection and maintenance of linear beam smoke detector, aspirating smoke detector, flame detector, manual call point, and strobe sounder.
Cabinet type FM200 gas suppression system is a portable fire-fighting equipment with automatic fire detection, alarm and fire extinguishing. Its performance is excellent, and its control part can be connected with the fire control center.
The fire extinguishing agent storage cylinder of the manifold type FM200 gas suppression system is usually placed in the special cylinder room and connected through the pipe network. When a fire occurs, the fire extinguishing agent will be conveyed from the cylinder to the protection area, and will be sprayed through the nozzle to extinguish the fire.
Check whether the configuration of the fire hydrant system is complete, including checking whether the static pressure of each fire hydrant meets the design or specification requirements
The inspection, test and maintenance of the gas fire suppression system is the guarantee to ensure the normal operation of the system when the fire occurs. Specific examples of 8 routine testing tasks.